Reports adopted

Incident Date

Report # or Accident #

Report title

Report /Adopted

6/28/2021

PLD-21-FR002-prelim

Preliminary Report, Farmersville, TX

8/2/2021

5/4/2020

PLD-20-LR001-prelim

Enbridge Inc. Natural Gas Pipeline Rupture and Fire, Hillsboro, KY

6/22/2020

Safety recommendations closed

Accident/Report title Rec. #      To: Recommendation Date Closed
Natural Gas-Fueled Building Explosion and Resulting Fire, Silver Spring, MD [8/10/2016] P-19-009 Washington Gas Light Company Throughout the Washington Gas network, implement an audit program to verify the data on the service forms used to determine the location and condition of mercury service regulators to ensure the accuracy of this safety-critical data. 8/6/2020
P-19-010 Washington Gas Light Company Revise your procedures and field forms to require technicians to verify the integrity of vent lines following the testing of indoor service regulators throughout the Washington Gas network. 8/6/2020
P-19-012 Washington Gas Light Company Install all new service regulators outside occupied structures. 8/6/2020
P-19-013 Washington Gas Light Company Relocate existing interior service regulators outside occupied structures whenever the gas service line, meter, or regulator is replaced. In addition, multifamily structures should be prioritized over single-family dwellings. 8/6/2020
Safety Study on Integrity Management of Gas Transmission Pipelines in High Consequence Areas [1/27/2015] P-15-004 PHMSA Increase the positional accuracy of pipeline centerlines and pipeline attribute details relevant to safety in the National Pipeline Mapping System. 7/16/2020
P-15-010 PHMSA Update guidance for gas transmission pipeline operators and inspectors on the evaluation of interactive threats. This guidance should list all threat interactions that must be evaluated and acceptable methods to be used. 7/16/2020
P-15-012 PHMSA Evaluate the safety benefits of the four risk assessment approaches currently allowed by the gas integrity management regulations; determine whether they produce a comparable safety benefit; and disseminate the results of your evaluation to the pipeline industry, inspectors, and the public. 7/16/2020
P-15-013 PHMSA Update guidance for gas transmission pipeline operators and inspectors on critical components of risk assessment approaches. Include (1) methods for setting weighting factors, (2) factors that should be included in consequence of failure calculations, and (3) appropriate risk metrics and methods for aggregating risk along a pipeline. 7/16/2020
P-15-021 PHMSA Develop and implement a plan for eliminating the use of direct assessment as the sole integrity assessment method for gas transmission pipelines. 7/16/2020
P-15-022 PHMSA Develop and implement a plan for all segments of the pipeline industry to improve data integration for integrity management through the use of geographic information systems. 7/16/2020